7-81
Symbologies
Redundancy Level 2
The following code types must be successfully read twice before being decoded:
Table 7-3. Redundancy Level 2 Code Types
Redundancy Level 2
Redundancy Level 3
Level 3 ensures that the enabled linear bar code types are read twice before reporting a
good decode. The following codes must be read three times:
Redundancy Level 3
Code Type Length
All All
Table 7-4. Redundancy Level 3 Code Types
Code Type Length
MSI 4 characters or less
D 2 of 5 8 characters or less
I 2 of 5 8 characters or less
Codabar 8 characters or less